Waykar CTH120-D fixed-vent dehumidifier review

Waykar CTH120-D is the CTH selector labelled 120 pints/day at 95°F/90% RH with a fixed vent. The exact page lists gravity drainage, but its standard-condition capacity, tank and pump details are not assigned to this hyphenated code.

Sources checked 2026-10-25 · Our editorial approach

Exact hyphenated selector CTH120-D, distinct from the no-hyphen CTH120D and the B-code version; fixed vent. The exact selected image is a shared family view.

We may earn from qualifying purchases. Compare the exact model, size and package.

White Waykar CTH dehumidifier with gray top control panel, top outlet grille and front water-level window; manufacturer image shared across selector variants.
Image source and model notes
Manufacturer CTH fixed-vent family exterior shared across capacity selectors; it does not identify this exact rating or model-specific operating details. Photo-versus-render status is not identified. Waykar — exact selected variant page, shared CTH selector-family exterior
A useful fit for

Consider this exact fixed-vent selector only if its humid-condition label and a verified gravity installation fit your room; obtain model-specific capacity and tank details before relying on a threshold or bucket plan.

The main tradeoff

The headline rating uses 95°F/90% RH, while no standardized rating is established. Fixed vent rules out auto-swing; tank volume, bucket collection, pump status and exact drain installation details remain unconfirmed.

On this page

Your needs, this model

Does it fit your priorities?

Does the 120-pint headline establish a standard-condition minimum?

No. Waykar lists 120 pints/day at 95°F/90% RH, but no exact standardized result is established for CTH120-D; do not rely on the headline for a 20-pint minimum.

Explore this need in the finder →
Can CTH120-D use the listed gravity-drain route?

The shared exact selector page lists gravity drainage (3.3 ft). Confirm the hose, route and fall for this hyphenated selector before a permanent installation.

Explore this need in the finder →
Does CTH120-D meet a requirement for an automatically moving outlet?

No. The exact variant title says Fixed Vent; exclude it when outlet swing is essential.

Explore this need in the finder →
Can CTH120-D be selected for a required bucket-collection plan?

The page assigns tank capacities to B-code selectors, not this hyphenated variant. Tank collection and capacity remain unconfirmed.

Explore this need in the finder →
Is model-specific ENERGY STAR status established for CTH120-D?

The family page says ENERGY STAR, but the exact hyphenated code is not matched in the saved EPA export. A required certification must not pass on the family claim.

Explore this need in the finder →
Is a pump-lift route confirmed for this exact model?

No. The 150-PD selector is the pump-equipped one; the 80-D and 120-D titles do not identify a pump. No lift requirement should pass by sibling inference.

Explore this need in the finder →

The Waykar CTH120-D is the 120-pint, fixed-vent selection shown on the CTH Pro page. That number belongs to the manufacturer’s 95°F/90% RH condition; it is not a verified standardized result for this hyphenated SKU. The larger label makes it a different choice from CTH80-D, but it does not resolve the manual, tank, or exact energy-rating questions. Keep it separate from the unhyphenated CTH120D, whose documentation belongs to a different selector.

Waykar’s exact U.S. variant page maps CTH120-D to variant 48173509869806 and GTIN 721820976442, labelled “120 Pints / Fixed Vent.” The shared product page lists 120 pints per day at 95°F/90% RH and a gravity-drain option. The quick guide names B-suffixed models, not CTH120-D; the unhyphenated CTH120D manual is not assumed to cover this identifier.

A higher headline is not a standardized capacity result

For a hot, moisture-heavy room, the 120-pint label tells you that Waykar places this selector in its larger removal tier under the stated 95°F/90% RH condition. It does not tell you how many pints it will remove in a cooler basement. No exact CTH120-D value at 65°F/60% RH is established here, so it cannot pass a 20-, 25-, or 35-pint threshold in the finder. That is conservative treatment of an unknown rating, not a claim that its real-world capacity is low.

Do not borrow the 32.46-pint Appendix X1 result associated with the separately listed CTH120D. That model has a different SKU and GTIN, and its own model-named manual. Similarly, the manufacturer page’s family-level ENERGY STAR statement is not enough to attach a specific certification record to CTH120-D. If an efficiency label or standardized capacity is central to the purchase, use the exact code printed on the offer and confirm that its test data match.

The fixed outlet is the reason to choose this version

CTH120-D is labelled “Fixed Vent,” while CTH120B is the auto-swing configuration. The distinction affects placement: a fixed outlet needs a clear direction into the space, and the listing does not promise automatic air distribution. A larger-capacity label does not compensate if your room needs the outlet to move. The product page describes the broader CTH Pro family as super quiet, but gives no decibel value for this SKU, so there is no model-specific sound threshold to compare.

The same page provides area and airflow figures for several capacities together, but does not explicitly tie each figure to CTH120-D in its table. I would not select it for a precise square-foot target based on an unassigned family number. Measure the area and, more importantly, the room’s moisture and temperature conditions; then obtain a model-specific performance table if the difference between the 80-, 120-, and 150-pint labels determines the purchase.

Drain setup needs a little more checking

The page lists gravity drainage with a 3.3-foot figure, making a nearby lower outlet the clearest documented route. It does not identify an included hose package, a minimum drop, or the capacity of the tank for CTH120-D. Do not carry over the 1.2-gallon tank assigned on the same page to CTH80B/CTH120B: those codes are explicitly different. The fixed-vent CTH120-D selector is not labelled pump-equipped, and the page’s 16.4-foot pump specification names CTH150PB, not this model.

If your installation has no lower drain, first confirm that the exact SKU has a fitted collection bucket and ask for its actual capacity. If the drain must rise, this page does not document a pump route for CTH120-D. A pump requirement should therefore reject it rather than assume a nearby 150-pint sibling’s hardware.

Where it fits in a shortlist

This is a plausible candidate when you specifically want the fixed-vent CTH Pro configuration, a large humid-condition label, and a room with a workable lower drain. It is not yet the evidence-led choice for a strict standardized capacity or energy requirement. The finder can show the current exact listing without constraints, while withholding it from standard-capacity, pump-lift, bucket, or app-control needs whose facts are missing. An auto-swing requirement should exclude it.

Compare CTH120-D with CTH120B if the moving outlet matters, and with CTH120D if verified EPA capacity, tank, and manual detail matter. These are not interchangeable model identities: Waykar’s fixed-vent hyphenated SKU has a distinct variant ID and GTIN. Until the manufacturer ties its documentation to that SKU, buy only if the listed configuration itself meets your needs and the seller can confirm the omitted operating details.

Key details at a glance

Published dimensionsNo model-specific cabinet dimensions or net weight are established for this hyphenated selector.
Capacity rating test conditionsWaykar lists 120 pints/day at 95°F/90% RH for selector CTH120-D; no exact standardized 65°F/60% RH or Appendix X1 value is established for this hyphenated SKU.

Use the exact model’s instructions for operating limits, supplied equipment and version differences.

Sources for this assessment

Check the route before the room-size claim.

Match the rated capacity and drainage setup to a real place for the water to go.