Does ADHR50LB meet a 50-pint/day rating threshold?
The exact GE specifications list 50 pints per day; room output depends on conditions.
Explore this need in the finder →Can ADHR50LB discharge condensate to a lower floor drain by gravity?
The manual documents a separate downhill hose and a securely seated bucket; the hose is not included.
Explore this need in the finder →Can ADHR50LB pump condensate to an outlet above the unit?
No pump lift is listed for this exact suffix. The gravity connector is not an upward pump.
Explore this need in the finder →The GE ADHR50LB is the non-pump 50-pint/day model in this older ADHR family. Its 15-pint front bucket is larger than the 8.5-pint tanks on ADHR22LB and ADHR35LB, but it still cannot hold a full day of rated extraction. Its distinguishing practical limitation is water routing: the exact model supports bucket collection or a downhill gravity hose, not a built-in uphill pump.
This earlier-model assessment uses the exact GE ADHR50LB page, its owner-support record and the ADHR22/35/50 manual 49-5000627 Rev. 0.
A larger capacity and bucket, with gravity drainage
GE lists 50 pints per day, a 15-pint bucket, 42.8 pounds net and dimensions of 24 1/8 × 14 1/2 × 11 1/2 inches. The cabinet is about five inches taller than the two smaller ADHR bodies, so compare more than its floor footprint: the unit needs clearance around its air inlet/outlet, and the front tank has to come out. Even its larger 1.875-gallon bucket is well short of the nominal 50-pint daily rating. If no one can empty it and no lower drain is available, the user’s routine can matter more than the capacity label.
The exact specifications list 200/160 CFM high/low airflow, an IEF of 1.8 L/kWh, 530 watts and 115 volts. GE lists 50 dBA at maximum and 47 dBA at low speed. Those are manufacturer figures; they are not independent sound tests, room measurements or a prediction of utility costs. The unit has three manual fan speeds and a separate Smart Dry mode that adjusts the fan in response to humidity.
Do not confuse ADHR50LB with a pump model
ADHR50LB has an external drain connector, but that does not mean it can lift water. The ADHR manual describes a garden hose routed downward to a floor drain and specifically requires the bucket to be securely reseated. The hose is not supplied. GE’s 50-pint family also includes pump-equipped models with different model numbers; those pump specifications do not transfer to the ADHR50LB. The nearby AWHR50LB shares the 50-pint rating and cabinet but is the Wi-Fi-listed, non-pump version. If the receiving drain is above the unit, do not treat either of these two connected/non-pump models as a solution; choose a separately documented pump configuration whose lift is adequate.
Humidity control and upkeep
The shared manual sets a 35%–80% RH range in five-point increments or permits Nonstop operation. The display is stated to be accurate within ±5%. It also documents a full-bucket alarm and stop, automatic defrost, auto restart after a power interruption and delay-on/off settings. A washable mesh filter catches ordinary dust but is not a substitute for a specialized filtration system. GE says to wash the filter at least every 250 operating hours, let it dry before reinstalling, and clean the water bucket every few weeks.
GE’s instructions limit the appliance to indoor residential use and specify operation from 41°F to 90°F, with at least 18 inches of open space on all sides. Avoid a closed closet or obstructed corner: the manual cautions that an adjacent enclosed area needs air circulation to dry. The 50-pint model is not listed as requiring the caster installation step that applies to the 22/35 models, but it still needs a level, strong floor that can support the appliance and a full bucket.
Its place in a current comparison
This model is useful for identifying an existing ADHR50LB or evaluating a specific earlier listing. GE labels it no longer manufactured; the support record dates production March 2022–November 2023. Neither statement establishes whether a seller has an unused unit or what warranty remains. The exact ADHR50LB page describes an ENERGY STAR-qualified model and publishes an IEF of 1.8, but it does not establish Wi-Fi in the exact specification row; generic connected-product page content is not enough to meet an app-control requirement. For a current 50-pint comparison, review the Frigidaire FHDD5034Y1 or another currently eligible model with the required water route. Read the exact pump or gravity plan before comparing rating alone.
Key details at a glance
| Published daily removal rating | 50 pt/day |
|---|---|
| Built-in lift pump | No |
| Published bucket capacity | 1.88 gal |
| ENERGY STAR certified | Yes |
| Published low-fan sound rating | 47 dBA |
| Published high-fan sound rating | 50 dBA |
| Published dimensions | 24.125 in H × 14.5 in W × 11.5 in D |
| Bucketless operating mode | No |
| Published product weight | 42.8 lb |
| Controls and settings | Manual specifies 35–80% RH in five-point steps or Nonstop, ±5% humidity-display accuracy, three manual fan speeds plus Smart Dry auto, 24-hour delay, auto restart, auto shutoff and automatic defrost. |
| Water-removal setup | A separate garden hose (not included) runs downhill to a floor drain. The bucket must be reinstalled and securely seated; neither family manual establishes bucketless or pump operation. |
| Care and operating limits | Clean the rear permanent mesh filter at least every 250 hours and let it dry before reinstalling; clean the bucket every few weeks. Indoor residential use only, 41°F–90°F and 18-inch clearance. The manual says 22/35-pint models require caster installation and one hour upright before use. |
| Published integrated energy factor | 1.8 L/kWh |