Your needs, this model
Does it fit your priorities?
Does Ultra V125 meet its exact 125-pint/day manufacturer rating threshold?
The exact page and data sheet list 125 pints/day at 80°F/60% RH and 101 at 73°F/60% RH. These are controlled test points, not guaranteed household extraction.
Explore this need in the finder →Can Ultra V125 run with bucketless gravity drainage rather than an uphill pump?
Yes only when the documented 3/4-inch gravity connection can reach a lower drain with the prescribed pitch. The base unit has no tank or built-in pump; a separate pump accessory does not meet an integral-pump need.
Explore this need in the finder →Does the exact EPA record for 4047200 meet its current IEF threshold?
EPA exact model number 4047200 lists certification and an IEF of 2.63 L/kWh. Santa Fe's manual table conflicts at 2.45 L/kWh; the matcher uses the current EPA exact record and preserves the version conflict.
Explore this need in the finder →Is Ultra V125 documented for whole-home HVAC duct integration?
Yes. The exact V-series manual calls it a fixed ventilating dehumidifier that integrates with heating and cooling duct systems; the return, supply, backdraft damper and static-pressure plan still require design.
Explore this need in the finder →Can Ultra V125 provide optional mechanically ducted outdoor air?
The exact model sheet/manual provide an optional 8-inch outdoor-air intake; a separate ventilation calculation, damper/control and code-compliant installation are still required.
Explore this need in the finder →Is the 104-pound dry Ultra V125 within a stated handling limit?
Santa Fe lists 104 pounds for the unit. This is not a safe-lifting recommendation; delivery, suspension supports and service access must be planned separately.
Explore this need in the finder →The Santa Fe Ultra V125 occupies the middle of the three-model V100/V125/V155 family: the manufacturer rates it at 125 pints per day at 80°F/60% RH and 101 pints at 73°F/60% RH, with application guidance up to 3,000 square feet. It keeps the same ducted whole-home installation concept as its siblings, so the right decision depends on the documented moisture load, duct design, drainage and service space—not the model number alone.
Sources are the exact V125 product page, the linked TS-2153 data sheet, the shared TS-2157 installation manual and the current EPA record for part 4047200. The raw manufacturer page/spec routes returned HTTP 403 from the local archive request; the manual and EPA JSON were saved, and the first-party pages were individually inspected in their rendered browser presentation rather than claimed as downloaded HTML.
Keep each rating in its own column
At 80°F/60% RH the current product page lists 125 pints per day and 5.9 pints per kilowatt-hour; at 73°F/60% RH it lists 101 pints and 5.2 pints/kWh. Those are two specified test conditions, not an expectation that a cooler basement or a duct system with resistance will collect exactly 101 pints every day. Santa Fe suggests up to 3,000 square feet, based on a ten-foot ceiling, but its manual calls for a ventilation/sizing calculation and the installer must account for air distribution, static pressure and the actual building load.
The EPA record for exact Santa Fe part 4047200 reports ENERGY STAR certification, 102.69 pints/day under Appendix X1, IEF 2.63 L/kWh and 565 kWh/year; it marks the model as meeting Most Efficient criteria. These are not interchangeable with the manufacturer page’s 125-pint 80°F rating or the separately named manufacturer Energy Factor. The manual itself contains a discrepancy: its April 2026 table gives the V125 a 101-pint 73°F/60% rating and IEF 2.45, while EPA’s current exact part record lists 102.69 and 2.63. I keep EPA’s value for the matcher’s certification/IEF question and preserve the manual table as a conflict to verify against the exact delivered revision, rather than silently choosing the number that makes the product look better.
Same system concept, not a plug-in 125-pint room unit
The V125 uses a fixed return-and-supply duct arrangement. Its exact sheet lists a vertical-or-horizontal airflow discharge, a 10-inch return and 10-inch supply connection, and an optional 8-inch fresh-air inlet. The shared manual’s recommended scheme draws from a central dedicated return and sends dry air to the HVAC supply; other duct options exist, but they depend on pressure and backdraft control. Manual guidance calls for at least 10-inch round duct up to 25 feet, at least 12 inches beyond that length, and reconfiguration if static pressure reaches 0.5 inches water gauge. Optional outdoor-air ventilation requires its own sizing and damper/control plan. A manufacturer-marketed 3,000-square-foot figure cannot compensate for an undersized duct, poor circulation path, or an unplanned ventilation load.
The cabinet is listed at 14.35 by 24 by 39.25 inches and 104 pounds, with a MERV-13 filter. A page note says “without collars,” while the data-sheet footnote says dimensions and weight are with collars; the collar-related depth is therefore not a dependable opening measurement. There is no exact published sound rating. R2 cabinet insulation is a construction feature, not a quantified noise result. The sheet lists 800 watts at 73°F/60% RH, 115 volts, R-454B and an installation circuit requirement; the manual calls for a grounded 120-volt supply with a minimum 15-amp circuit. Have the current nameplate and local electrical requirements checked before installation. The included hardwire kit and remote-control terminals do not mean Wi-Fi or app control; those features are not established for this exact product.
Gravity is standard; pump lift is not
There is no tank or integral condensate pump. The normal plan drains by gravity through a 3/4-inch threaded connection and PVC pipe. Santa Fe’s shared manual requires about a quarter inch of fall per foot, a drain outlet at least 6.75 inches below the unit outlet arrangement for the trap, and secondary-pan/float protection when installed over a finished area. A separate condensate-pump kit is available if the layout requires lift, but it is an accessory and the model materials do not specify its numeric lift ceiling. The questionnaire should match this V125 only when bucketless gravity is genuinely workable; do not turn “pump accessory available” into a confirmed built-in pump or a numeric lift score.
What does V125 change in the choice?
It is the defensible middle choice when the installation plan calls for more rated removal than V100’s 100/82-pint pair but does not require the V155’s 155/128-pint ratings, higher airflow and ECCO feature. Compared with V100, the V125 is three pounds heavier and lists 800 rather than 620 watts at 73°F/60% RH; the shared footprint means it still requires the same kind of duct, drain and service-access planning. The V155 is 8 pounds heavier and has separate higher airflow and efficiency claims. If you only need a movable appliance or cannot guarantee downward drainage, compare Santa Fe’s stand-alone family rather than treating the V125 as portable. Confirm the exact 4047200 part, rating method, ventilation need, gravity slope, filter access, control location and current manual before committing.
Key details at a glance
| Published daily removal rating | 125 pt/day |
|---|---|
| Built-in lift pump | No |
| ENERGY STAR certified | Yes |
| Published dimensions | Exact detail page lists 14.35 × 24 × 39.25 inches while labeling dimensions without collars; manufacturer sheet footnote says unit dimensions and weight are with collars. The difference is retained; do not treat the nominal cabinet figure as an opening or clearance guarantee. |
| Bucketless operating mode | Yes |
| Published product weight | 104 lb |
| Controls and settings | Exact page states onboard digital controls plus 24-V AC terminal block/on-board power. Separate DEH 3000/R or SmartAire remote sensor/damper options require separate purchase and setup. App control not documented. |
| Published integrated energy factor | 2.63 L/kWh |
Use the exact model’s instructions for operating limits, supplied equipment and version differences.
Sources for this assessment
- Santa Fe exact U.S. Ultra V125 product page
- Santa Fe Ultra V100/V125/V155 installation and operation instructions, TS-2157 04/26 Rev H
- Santa Fe Ultra V125 TS-2153 Rev A, 08/25 (official rendered PDF search view; local request 403) data sheet
- EPA ENERGY STAR exact Santa Fe part 4047200 current dehumidifier record
- Santa Fe Ultra Series category image linked for exact Ultra V125 listing
Check the route before the room-size claim.
Match the rated capacity and drainage setup to a real place for the water to go.