Model assessment · Santa Fe

Santa Fe Ultra98 Whole-Home Dehumidifier review

A fixed ducted whole-home ventilating dehumidifier with an optional outdoor-air intake, external low-voltage control and gravity-drain installation.

Sources checked 2026-10-24 · Our editorial approach

We may earn from qualifying purchases. Compare the exact model, size and package.

Three-quarter view of the white Santa Fe Ultra98 ducted dehumidifier cabinet with Santa Fe logo and dark round duct collars.
The TS-2112 sheet identifies model 4044300 and the pictured cabinet. The image shows exterior form, not an installation, operating result or included external pump. Santa Fe does not state whether this artwork is a photograph or render. Santa Fe — embedded product image in the exact-part 4044300 R454B manufacturer data sheet
A useful fit for

For a qualified whole-home HVAC installation where the exact Santa Fe part 4044300, 100-pint/day rating at 80F/60% RH, optional outdoor-air provision and bucketless gravity drain fit the duct, control and service layout. The 2,300-square-foot figure is manufacturer guidance, not a load calculation.

The main tradeoff

Ultra98 is a compact horizontal fixed unit, but it needs an external control and planned ductwork, a trapped lower gravity drain and maintenance access. No built-in pump, bucket, app control or current exact EPA ENERGY STAR record is confirmed. Dimensions and warranty statements have source discrepancies that should be checked before installation or purchase.

Your needs, this model

Does it fit your priorities?

Does the manufacturer’s 100-pint/day rating at 80F/60% RH meet your threshold?

The exact 4044300 page and sheet say 100 pints/day at 80F/60% RH, but list 71.4 pints/day at the separate 73F/60% point. Treat these as test conditions, not predicted house yield.

Explore this need in the finder →
Can your planned installation use a continuous bucketless gravity drain?

Yes if the required trapped 3/4-inch PVC route can fall continuously to a lower drain. The base model has no tank or integral pump; the optional separate pump has no verified lift limit in the reviewed documents.

Explore this need in the finder →
Do you need a fixed HVAC-ducted unit with optional outdoor-air ventilation?

The manual supports HVAC integration and an optional 6-inch outdoor-air connection, but duct pressure, airflow, controls and building ventilation need a qualified design.

Explore this need in the finder →
Does the manual’s exact 2.217 L/kWh Integrated Energy Factor meet your minimum?

Yes at a 2.21 L/kWh minimum: the exact TS-2096 registration table reports 2.217 L/kWh. A 2.22 minimum is not met; the questionnaire accepts hundredth-step values, so it cannot encode 2.217 as a user threshold.

Explore this need in the finder →
Is a documented ENERGY STAR certification essential?

The exact EPA model-number lookup returned no row as checked; this source set does not confirm ENERGY STAR for the Ultra98. It can be considered only when certification is not an essential requirement.

Explore this need in the finder →
Will the 81-pound listed fixed unit stay below your dry-weight limit?

The manufacturer lists 81 pounds. That is useful for delivery and support planning, not a recommendation to lift the unit without assistance.

Explore this need in the finder →
Do you require app control rather than an external low-voltage control?

The manual requires external 24-V low-voltage control and says the DEH 3000 is sold separately; app/Wi-Fi control is not documented. An app-essential answer should exclude this model.

Explore this need in the finder →

The Santa Fe Ultra98 (part 4044300) is a fixed, ducted whole-home dehumidifier, not a portable room unit. It is worth considering when a planned HVAC installation needs a 100-pint-per-day warm-condition rating, an optional outdoor-air intake and a compact horizontal cabinet. Its installation details matter as much as the headline capacity: a remote low-voltage control is required, and the standard water route is a trapped gravity drain.

This assessment uses Santa Fe’s exact U.S. Ultra98 page, the 4044300 R454B data sheet, the Ultra98/120 installation manual and Santa Fe’s Ultra Series performance chart. A current exact-number EPA lookup for part 4044300 returned no record; the manufacturer manual’s registration table and energy-factor labels are not treated as proof of current ENERGY STAR certification.

Two capacity numbers, two test points

Santa Fe lists 100 pints per day at 80°F and 60% relative humidity, and 71.4 pints per day at 73°F and 60% RH. These are manufacturer test ratings, not a guarantee of what a particular basement or house will yield. The advertised “up to 2,300 square feet” is sizing guidance based on a ten-foot ceiling, not a substitute for a moisture-load calculation. The same sheet gives 6.12 and 4.68 pints per kilowatt-hour at those respective test points. A separate table labels energy factor as 2.89 and 2.2 L/kWh; neither label is an electricity-bill estimate.

The exact manual’s registration table separately identifies the 4044300 as basic model 98.1-W and lists a 2.217 L/kWh Integrated Energy Factor at 73°F/60% RH, while the manufacturer data sheet calls 2.2 L/kWh an Energy Factor. Those labels are not interchangeable. The current exact EPA dataset query returned no 4044300 record when checked, so certification should be verified from a current listing or nameplate rather than inferred from the manufacturer’s efficiency language. This is a poor fit if a documented ENERGY STAR model is essential.

Plan ducts and service access before choosing a location

The Ultra98 is a fixed ventilating appliance. The manual provides a 10-inch return and 10-inch supply connection, with a separate optional 6-inch outdoor-air intake; the discharge panel can be reoriented for horizontal or vertical flow. The manufacturer says duct layout should be designed with the HVAC system, a backdraft damper and adequate access. Its optional ventilation needs a separate control and airflow plan. A 6-inch collar does not establish the amount of fresh air a particular home should receive, and the manual warns that outdoor-air conditions can affect performance. If you only want a plug-in unit for one room, this is the wrong installation class.

Its 81-pound listed weight is lighter than the 101-pound Ultra V100, but this is still a fixed appliance that needs proper delivery, support and qualified installation. Dimension language is inconsistent: the product page labels 14.5 × 19.5 × 32.4 inches “without collars” and also lists a 26-inch length; the exact sheet says the 32.4-inch dimensions are with collars. Treat those as planning figures only. Measure the cabinet, duct-collar envelope, filter pullout and service clearances on the current unit before building a closet or hanging support.

Gravity drainage is the base plan

There is no collection bucket or built-in condensate pump. Santa Fe’s manual requires a drain trap, a 3/4-inch threaded male NPT adapter and a continuously falling PVC drain pitched about one inch per ten feet. Where leakage could damage a finished area, the manual calls for a secondary drain pan with a float switch. The optional separate condensate-pump kit can be added when gravity cannot reach a drain, but it is not included and the reviewed manufacturer sources do not give a lift-height limit. Do not choose this model on the assumption that it can pump upward; plan the accessory and route with an installer first.

Controls and upkeep are part of ownership

The product page specifies a low-voltage terminal block and requires an external control. The manual says a control must be used and notes that Santa Fe’s DEH 3000 is sold separately; other compatible thermostats may also be used. The model is not documented as Wi-Fi or app-controlled. A MERV-13 filter is included, with a three-to-six-month inspection or replacement interval in the manual. The filter slides out from either side, so leave room to reach it. Filter neglect reduces capacity and efficiency; the rating is a filter specification, not a claim that the appliance treats a health condition.

The exact product page advertises a six-year warranty, but the 2024 manual describes a five-year limited product warranty and six years for components. Those statements may reflect different warranty summaries or revisions. Read the warranty supplied with the exact part and verify coverage, labor and installation conditions before purchase. The R454B version’s installation and service are work for qualified HVAC professionals, not a casual room-appliance setup.

Who should compare it with the Ultra V100?

The Ultra98 and Ultra V100 both carry a 100-pint/day manufacturer rating at 80°F/60% RH, but they are not interchangeable versions. The Ultra98 is listed at 71.4 pints/day at 73°F/60% RH, compared with 82 for the V100. Ultra98 uses an external low-voltage control; the V100 has onboard digital controls plus terminals. Their manuals also show different cabinet envelopes, weight and intake layout. If a documented current EPA certification is a priority, the V100 has an exact EPA record while the Ultra98 lookup did not return one. Compare the exact part number and current manual, not just “100” in the model name.

Choose the Ultra98 only when the whole-home duct plan, gravity-drain elevation, separate control and service access all work together. If the drain must rise, the included configuration is not enough; if you need casters, a bucket, built-in pump or app control, look at other documented operating plans. Before ordering, confirm the 4044300 part number, the R454B manual revision, the actual duct and drain dimensions, the external controller and warranty with the installer or seller.

Key details at a glance

Published daily removal rating100 pt/day
Built-in lift pumpNo
Published dimensionsExact product-page lines say 14.5x19.5x32.4 inches without collars and separately 14.5x19.5x26 inches; TS-2112 says 14.5x19.5x32.4 inches and footnotes dimensions/weight with collars. Preserve the discrepancy, verify the actual unit and duct/service envelope before fitting.
Bucketless operating modeYes
Published product weight81 lb
Controls and settingsA remote 24-V low-voltage control must be used. DEH 3000 is sold separately; manual says other compatible thermostats can also be used. No app/Wi-Fi capability is documented.
Published integrated energy factor2.22 L/kWh

Use the exact model’s instructions for operating limits, supplied equipment and version differences.

Sources for this assessment

Check the route before the room-size claim.

Match the rated capacity and drainage setup to a real place for the water to go.