Model assessment · Haier

Haier 70 Pint Electronic-Control Dehumidifier review

Earlier 70-pint/day Haier portable model with an 18-pint tank and bucket or downhill gravity drainage; no built-in pump is documented.

Sources checked 2026-10-23 · Our editorial approach

Earlier Haier reference; confirm full model suffix and unit condition.

We may earn from qualifying purchases. Compare the exact model, size and package.

Front view of the white HEN70ETF cabinet with top outlet and controls. This is the same original image byte set linked from the HEN70ETFP support page
Front view of the white HEN70ETF cabinet with top outlet and controls. This is the same original image byte set linked from the HEN70ETFP support page; the image cannot show whether the internal pump is fitted. Haier does not label photo-versus-render status. Haier — exact HEN70ETF official U.S. product/support page-linked gallery asset
A useful fit for

For an owner identifying HEN70ETF where the documented fitted bucket or lower gravity drain matches the existing installation.

The main tradeoff

The 18-pint tank remains much smaller than the 70-pint/day rating; this exact suffix is bucket/gravity only and discontinued.

Your needs, this model

Does it fit your priorities?

Does HEN70ETF meet a 70-pint/day minimum?

The exact page lists 70 pints/day; that is a published rating, not a guaranteed room result.

Explore this need in the finder →
Can HEN70ETF drain by gravity to a lower outlet?

Yes. Its manual documents a separate hose routed downward and requires the collection bucket to remain installed.

Explore this need in the finder →
Can HEN70ETF pump water up to a raised drain?

No pump appears in the exact non-P suffix specifications or the HEN70ET/HEN70ETF manual.

Explore this need in the finder →

The Haier HEN70ETF is an earlier 70-pint/day portable dehumidifier with an 18-pint front bucket, two fan speeds plus Smart Dry, and a gravity-only direct-drain route. It is the non-pump sibling to the HEN70ETFP: the shared cabinet and rating do not make their drainage interchangeable. Haier says HEN70ETF is no longer manufactured, so this page is an owner and exact-model reference rather than a current buying recommendation.

Sources personally checked: the Haier HEN70ETF page, its matching support record, the model-cover HEN70ET/HEN70ETF Installation and User Manual and the 2020 U.S. Haier catalog. The exact support record dates manufacture March 2018–January 2020.

Seventy pints does not mean an unattended bucket

Haier lists a 70-pint daily rating and an 18-pint bucket. The cabinet is 24 inches high by 15.12 wide and 10¾ deep; its listed net weight is 43.8 pounds. Compared with the HEH50ET, it is taller, heavier and holds seven more pints in the tank, but its bucket still cannot contain a full day at the nominal rating. A bucket-only owner should plan to check the full indicator and audible alarm rather than estimating a day’s use from the capacity label. The unit stops when full and resumes only after the tank is emptied and correctly seated.

The exact product page lists two manual fan speeds and Smart Dry. That gives a simple manual choice plus an automatic humidity-responsive mode, not a third manual speed. Haier lists high/low airflow of 170/148 CFM, 820 watts, 7.5 amps at 115 volts, and R410A refrigerant. The product page identifies HEN70ETF as ENERGY STAR qualified. These are manufacturer numbers; there is no independent room-performance or sound test here, and a standardized rating cannot promise a particular energy bill or moisture removal rate.

Gravity only: confirm where the drain sits

The HEN70ETF manual allows a direct drain if you want continuous operation near a floor drain. Its installation page says to remove the rear cover and rubber stopper, connect a separate garden-hose-style drain hose, lower the hose to the drain, and keep the collection bucket inserted correctly. The hose is not supplied. The route must descend to the outlet; there is no pump in the exact HEN70ETF specifications and no pump setup in the manual. The unit cannot be counted on to push condensate up to a utility sink, window or elevated standpipe.

This is the key suffix boundary. Haier’s adjacent HEN70ETFP page describes a built-in pump and supplies a 16-foot drain tube, but the HEN70ETF manual cover lists HEN70ET and HEN70ETF—not the pump suffix. HEN70ETF owners cannot inherit the pump’s tube or function from a similar front image, family listing or neighboring model number. If your outlet is raised, look for a current exact model with a published pump route and lift rating; HEN70ETF’s lift field remains unknown, so it fails any essential pump-height need.

Controls, cold-room caution and care

The manual sets a practical minimum: below 54°F the evaporator may frost and the machine enters periodic defrost, and if the room stays below 41°F it should be turned off. It recommends at least 8 inches of open space around the cabinet and says not to operate without the washable filter. Allow air to enter at the rear and leave through the top; leave room in front to extract the bucket. If the machine has been tilted, wait the manual’s stated 24 hours before restarting to allow oil to return to the compressor.

The rear filter should be vacuumed or washed and allowed to dry before it is reinstalled. Unplug the appliance before cleaning; do not spill liquid onto the controls or wash the cabinet with a hose. The filter captures ordinary dust, not a specialty contaminant, and nothing in these specifications supports a medical or mold-remediation claim. The 18-pint tank and caster base help with routine movement, but the empty unit is already over 43 pounds before adding water. Plan a stable, level placement and do not carry a full bucket through stairs.

When this earlier model still matters

HEN70ETF is a useful identification reference if the exact nameplate matches a unit already in a basement or a seller’s listing. For a smaller cabinet, the HEN30ET review explains the 30-pint rating and 7-pint tank; for a shorter 50-pint option, compare the HEH50ET. For the pump sibling, read the separate HEN70ETFP recall-focused review and do not treat it as a purchase alternative. All four exact Haier pages say their models are no longer manufactured; a seller’s listing does not establish warranty, service, unit condition or safe serial-number status.

If you need a current 70-pint dehumidifier, use the finder and filter by the water route you can actually install. A lower drain may make a non-pump model practical; a raised outlet demands a documented pump arrangement, not just a 70-pint rating. HEN70ETF’s published facts help distinguish a known earlier gravity model, but they are not a claim that this exact appliance is available or suitable for every damp room.

Key details at a glance

Published daily removal rating70 pt/day
Built-in lift pumpNo
Published bucket capacity2.25 gal
Wi-Fi enabledNo
ENERGY STAR certifiedYes
Published dimensions24.0 in H × 15.12 in W × 10.75 in D
Bucketless operating modeNo
Published product weight43.8 lb
Controls and settingsElectronic local humidity control, full-bucket alarm/shutoff and automatic defrost. Smart Dry is listed only for the exact HEH50ET and HEN70ETF models; it is an automatic mode, not an extra manual speed.
Water-removal setupExact manual supports a separately purchased garden-hose-style gravity route to a lower drain; it is not an uphill pump. Bucket-seating details are recorded per exact plan and remain unknown where manual instructions do not state them.
Care and operating limitsKeep the removable filter installed, clean it periodically and dry it before reinstalling if washed. Manuals say turn the unit off below 41°F and describe defrost below 54°F. Observe exact clearance and post-tilt instructions.

Use the exact model’s instructions for operating limits, supplied equipment and version differences.

Sources for this assessment

Check the route before the room-size claim.

Match the rated capacity and drainage setup to a real place for the water to go.